| | | | Medium Voltage Cables |
| | |
1 |
IEC 60502-2 |
6.35/11 (12) kV |
1 X 500 mm2 |
CU/XLPE/CTS/ AWA/PVC |
KEMA |
2018 |
|
2 |
IEC 60502-2 |
6/10 (12) kV |
3 X 70 mm2 |
CU/XLPE/CTS/ SWA/PVC |
KEMA |
2009 |
|
3 |
IEC 60502-2 |
6.35/11 (12) kV |
3 X 240 mm2 |
CU/XLPE/CTS/ SWA/PVC |
KEMA |
2018 |
|
4 |
IEC 60502-2 |
6/10 (12) kV |
3 X 300 mm2 |
CU/XLPE/CTS/ SWA/PVC |
KEMA |
2011 |
|
5 |
IEC 60502-2 |
19/33 (36) kV |
3 X 300 mm2 |
CU/XLPE/CTS/ SWA/PVC |
KEMA |
2018 |
|
6 |
ADWEA |
19/33 (36) kV |
3 X 240 mm2 |
CU/XLPE/CTS+ IC/PE/STA/PE/SCPE |
KEMA |
2010 |
|
7 |
ADWEA & AEIC CS8-07 |
19/33 (36) kV |
3 X 240 mm2 |
CU/XLPE/CTS+ IC/PE/STA/PE/SCPE |
KEMA |
2010 |
|
8 |
DEWA |
6.35/11 (12) kV |
3 X 300 mm2 |
CU/XLPE/CTS/PE /PVC/SWA/PE |
KEMA |
2010 |
|
9 |
IEC 60502-2 |
18/30 (36) kV |
3 X 300 mm2 |
AL/XLPE/CTS/PVC/SWA/PVC |
KEMA |
2022 |
|
10 |
SECO |
8.7/15 (17.5) kV |
3 X 240 mm2 |
CU/XLPE/CWS/PE /STA/PVC |
KEMA |
2009 |
|
11 |
SECO |
18/30 (36) kV |
1 X 500 mm2 |
CU/XLPE/CWS/PVC |
KEMA |
2009 |
|
12 |
KAHRAMAA |
6.35/11 (12) kV |
3 X 300 mm2 |
CU/XLPE/CWS/ SWA/PVC |
KEMA |
2009 |
|
13 |
CENELEC HD 620 S2 |
6.35/11 (12) kV |
1 X 240 mm2 |
CU/SEMICON/ XLPE/SEMICON |
KEMA |
2014 |
|
14 |
IEC 60502-2 |
19/36 (36) kV |
1 X 630 mm2 |
CU/XLPE/CTS/PVC/AWA/PVC |
KEMA |
2014 |
|
15 |
IEC 60502-2 & ADDC |
19/36 (36) kV |
3 X 400 mm2 |
AL/XLPE/CWS/PE/SWA/PE |
UL |
2024 |
|
| | | | Low Voltage Power & Control Cables |
| | |
1 |
BS 5467 |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
BSI |
2008 |
|
2 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 95 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2007 |
|
3 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 185 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2008 |
|
4 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 240 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2008 |
|
5 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2009 |
|
6 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 400 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2009 |
|
7 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 95 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2007 |
|
8 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2009 |
|
9 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 400 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2009 |
|
10 |
BS 5467 |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
KEMA |
2013 |
|
11 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 120 mm2 |
CU/XLPE/SWA/PVC |
KEMA |
2013 |
|
12 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
CU/XLPE/SWA/PVC |
KEMA |
2013 |
|
13 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
KEMA |
2013 |
|
14 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 120 mm2 |
CU/XLPE/SWA/PVC |
KEMA |
2013 |
|
15 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
CU/XLPE/SWA/PVC |
KEMA |
2013 |
|
16 |
ADWEA Colour Test |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
KEMA |
2013 |
|
17 |
ADWEA Colour Test |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
CU/XLPE/SWA/PVC |
KEMA |
2013 |
|
18 |
MEW, Kuwait |
0.6/1.0 (1.2) kV |
1 X 800 mm2 |
CU/XLPE/PVC |
KEMA |
2011 |
|
19 |
MEW, Kuwait |
0.6/1.0 (1.2) kV |
3X35 mm2+ 2X16 mm2 |
CU/XLPE/PVC |
KEMA |
2011 |
|
20 |
BS 5467 |
0.6/1.0 (1.2) kV |
19 X 2.5 mm2 |
CU/XLPE/SWA/PVC |
BSI |
2009 |
|
21 |
BS 5467 |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
DEKRA |
2021 |
|
22 |
BS 5467 |
0.6/1.0 (1.2) kV |
4 X 185 mm2 |
CU/XLPE/SWA/PVC |
DEKRA |
2021 |
|
23 |
BS 5467 |
0.6/1.0 (1.2) kV |
7 X 2.5 mm2 |
CU/XLPE/SWA/PVC |
DEKRA |
2021 |
|
24 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
1 X 630 mm2 |
CU/XLPE/AWA/PVC |
DEKRA |
2021 |
|
25 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 185 mm2 |
CU/XLPE/SWA/PVC |
DEKRA |
2021 |
|
26 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
7 X 2.5 mm2 |
CU/XLPE/SWA/PVC |
DEKRA |
2021 |
|
27 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 35 mm2 |
AL/XLPE/SWA/PVC |
DEKRA |
2021 |
|
28 |
IEC 60502-1 |
0.6/1.0 (1.2) kV |
4 X 300 mm2 |
AL/XLPE/SWA/PVC |
DEKRA |
2021 |
|
29 |
BS EN 50525-2-21 |
450/750 V |
3 X 2.5 mm2 |
H07RN-F & H07RN8-F |
DEKRA |
2022 |
|
30 |
BS EN 50525-2-21 |
450/750 V |
1 X 300 mm2 |
H07RN-F |
DEKRA |
2024 |
|
| | | | House Wiring Cables |
| | |
1 |
BS EN 50525-2-31 |
450/750 V |
1 X 2.5 mm2 |
CU/PVC, H07V-R |
KEMA |
2013 |
|
2 |
BS EN 50525-2-31 |
450/750 V |
1 X 120 mm2 |
CU/PVC, H07V-R |
KEMA |
2013 |
|
3 |
BS EN 50525-2-11 |
300/500 V |
3 X 2.5 mm2 |
CU/PVC/PVC, H05VV-F |
KEMA |
2013 |
|
4 |
BS EN 50525-2-31 |
450/750 V |
1 X 2.5 mm2 |
CU/PVC, H07V-R |
DEKRA |
2021 |
|
5 |
BS EN 50525-2-31 |
450/750 V |
1 X 630 mm2 |
CU/PVC, H07V-R |
DEKRA |
2021 |
|
6 |
BS EN 50525-2-11 |
300/500 V |
3 X 2.5 mm2 |
CU/PVC/PVC, H05VV-F |
DEKRA |
2021 |
|
| | | | Instrumentation Cables |
| | |
1 |
BS 5308-1 |
300/500 V |
12P X 1.0 mm2 |
CU/PE/IOSCR/SWA/PVC |
BSI |
2009 |
|
2 |
BS 5308-2 |
300/500 V |
2 X 1.5 mm2 |
CU/PVC/OSCR/PVC |
BSI |
2007 |
|
3 |
BS 5308-2 |
300/500 V |
4 X 1.5 mm2 |
CU/PVC/OSCR/PVC |
BSI |
2007 |
|
4 |
BS 5308-2 |
300/500 V |
5P X 1.5 mm2 |
CU/PVC/IOSCR/SWA/PVC |
BSI |
2007 |
|
5 |
BS EN 50288-7 |
300/500 V |
10P X 1.5 mm2 |
CU/XLPE/IOSCR/PE/SWA/PVC |
DEKRA |
2016 |
|
| | | | LSF/LSOH Wires & Cables |
| | |
1 |
BS 7211 |
450/750 V |
1 X 2.5 mm2 |
CU/LSF |
BSI |
2008 |
|
2 |
BS 7211 |
450/750 V |
4 X 2.5 mm2 |
CU/LSF/LSF |
BSI |
2008 |
|
3 |
BS 6724 |
0.6/1.0 (1.2) kV |
4 X 25 mm2 |
CU/XLPE/SWA/LSF |
BSI |
2008 |
|
4 |
BS 6724 |
0.6/1.0 (1.2) kV |
4 X 240 mm2 |
CU/XLPE/SWA/LSF |
BSI |
2009 |
|
5 |
BS 6724 |
0.6/1.0 (1.2) kV |
19 X 2.5 mm2 |
CU/XLPE/SWA/LSF |
BSI |
2009 |
|
6 |
BS EN 50525-3-41 |
450/750 V |
1 X 2.5 mm2 |
CU/LSF, H07Z-R |
DEKRA |
2021 |
|
7 |
BS 6724 |
0.6/1.0 (1.2) kV |
4 X 185 mm2 |
CU/XLPE/SWA/LSF |
DEKRA |
2021 |
|
8 |
BS EN 50525-3-11 |
300/500 V |
3 X 4 mm2 |
CU/LSZH/LSZH – H05Z1Z1-F |
DEKRA |
2021 |
|
9 |
BS EN 50618 |
1500 V DC |
1 X 6 mm2 |
PV (SOLAR) – H1Z2Z2-K |
DEKRA |
2021 |
|
| | | | Fire Resistant Cables |
| | |
1 |
BS 7846 |
0.6/1.0 (1.2) kV |
4 X 10 mm2 |
CU/MGT/XLPE/SWA/LSF |
BSI |
2009 |
|